Particles carry a surface charge
Suspended particles usually carry a surface charge that keeps them apart. Polymer charge can reduce that repulsion so particles come together.
Charge is only part of the picture. Solids concentration, mixing and process chemistry also affect whether particles aggregate.
Charge neutralization
A polymer of opposite charge can neutralize the particle surface and allow contact. This mechanism is sensitive to the charge level of both polymer and feed.
Check the result at several active doses. Too little leaves particles dispersed and too much can restabilise them.
Bridging between chains
A long polymer chain can attach to more than one particle and build a larger aggregate. Higher molecular weight favors this bridging mechanism.
Bridged floc can be large but fragile. Test how it responds to mixing and transfer before selecting a grade.
Mixing controls the outcome
Rapid dispersion and slower floc development both matter. Too little mixing leaves polymer unused; too much shear breaks the floc.
Use a repeatable mixing sequence in every test and record speed and time so results can be compared.
Measure the result, not the theory
Charge and bridging explain behavior, but acceptance should rest on liquid clarity, residual solids, settling or drainage.
Keep photographs as support, not as the decision. Quantitative measurements on the current feed carry the decision.
Re-screen when chemistry changes
A change in pH, salinity or upstream coagulant can alter particle charge and chain behavior.
Re-test on the current feed after a material process change instead of assuming the old grade still applies.
Judge floc strength with a transfer step
Pour the flocculated sample once through a beaker transfer and observe whether aggregates survive. Large floc that breaks on transfer will also break in a pump or pipe.
Keep the transfer step identical between candidate grades so the comparison reflects floc strength, not handling differences.
Watch the supernatant, not only the floc
A clear supernatant with small, dense floc often separates better than a large, loose floc that traps water. Clarity and settling rate answer different questions.
Measure supernatant turbidity or settling height at a fixed time, alongside floc appearance, before choosing a grade.
Over-dosing leaves a signature
Excess polymer can restabilise particles, raise supernatant turbidity and increase solution viscosity. These signs point to a dose problem before they point to a wrong product.
Run a dose series and look for the point where quality stops improving or reverses, rather than stopping at the first visible floc.
Judge floc after mixing, not only at formation
A floc that forms quickly in a beaker can break when it is pumped or transferred. Apply a defined mixing step and observe whether the aggregates rebuild.
Use shear recovery as part of screening. A grade that recovers is usually safer to scale than one that only looks good under gentle mixing.
Use over-dosing as a diagnostic
When clarity worsens as the dose rises, the likely cause is charge reversal or restabilisation rather than underfeed.
Step the dose back through the last good point and confirm before changing product; a higher setting is not always a safer one.
Separate shear damage from weak chemistry
A floc that breaks after pumping may be chemically sound but physically overworked at the injection point or a downstream pump.
Check the addition sequence and pump selection before blaming the grade, and move the dose point or reduce shear first.
Place the polymer in the addition sequence
Where a coagulant is used, it destabilises particles first and the polymer then builds floc. Reversing that order or dosing at the same point can waste both chemicals.
Record the injection points and the time between them. Confirm the sequence on the real stream before fixing the dose.
Move the injection point before raising the dose
A poorly placed feed gives too little contact time or too much shear. The same grade can perform very differently when the dose point moves.
Map pumps, mixers and residence time, then run a controlled step test with stop limits instead of jumping straight to the visually strongest response.
Read overdosing in the liquid, not only the floc
Excess polymer can leave fine strings in the liquid, raise residual polymer or make the supernatant viscous, even while the settled solids look acceptable.
Include liquid quality and residual checks in the dose curve and choose the lowest stable region that meets every endpoint.

